60L Urea Tank
Бачок Мочевины 60Л
Tanque de Urea 60L
This OEM 60L urea tank (part DZ9X259745022) is a precision-manufactured SCR aftertreatment storage component designed specifically for Shacman H3000 heavy-duty commercial trucks. The DZ9X259745022 60L urea tank provides reliable storage of diesel exhaust fluid with integrated level sensing and heating functions, ensuring proper SCR system operation and NOx emissions reduction under all vehicle operating conditions.
Manufactured from premium high-quality urea-resistant polymer with exact dimensional specifications, advanced molding and assembly processes, and durable construction, this DZ9X259745022 60L urea tank withstands extreme temperature variations, continuous vibration stress, harsh under-chassis environmental exposure, and prolonged intensive operation during demanding heavy-duty commercial vehicle applications.
Replacing a damaged, leaking, or contaminated urea tank with this genuine DZ9X259745022 component restores proper SCR system function and emissions compliance. The OEM part number guarantees exact dimensional specifications and factory-engineered quality specifically validated for Shacman truck platforms.
| Parameter | Specification |
|---|---|
| OEM Part Number | DZ9X259745022 |
| Product Name | 60L Urea Tank |
| Brand | Shacman |
| Application | Vehicle SCR Aftertreatment System – Diesel Exhaust Fluid Storage |
| Capacity | 60 Liters – Diesel Exhaust Fluid (AdBlue/DEF) |
| Tank Type | Molded Urea-Resistant Polymer Tank with Integrated Level Sensor and Heating |
| Material | High-Quality Urea-Resistant Polymer with Precision Molding |
| Function | Reliable Storage of Diesel Exhaust Fluid with Integrated Level Sensing and Heating for SCR System |
The DZ9X259745022 60L urea tank serves as a vital SCR aftertreatment storage component engineered to provide reliable containment and management of diesel exhaust fluid on Shacman H3000 heavy-duty commercial trucks.
This DZ9X259745022 60L urea tank stores AdBlue/DEF solution and supplies it to the SCR dosing system through integrated level sensing and heating functions, ensuring proper fluid condition monitoring and freeze protection under all climate conditions.
The precisely engineered 60-liter capacity of the DZ9X259745022 provides sufficient diesel exhaust fluid storage for extended vehicle operation between refills, enabling efficient long-haul transport operations without frequent DEF replenishment stops.
This DZ9X259745022 component features integrated level sensing that provides accurate DEF quantity information to the vehicle instrument cluster, allowing drivers to monitor fluid levels and plan timely refills to maintain continuous SCR system operation.
The high-quality urea-resistant polymer construction of the DZ9X259745022 provides excellent chemical compatibility and structural durability, withstanding continuous exposure to diesel exhaust fluid, temperature variations, and under-chassis conditions throughout the vehicle service life.
The DZ9X259745022 60L urea tank is manufactured to meet the specific capacity, mounting pattern, and connection interface requirements of Shacman H3000 SCR aftertreatment systems, assuring complete compatibility and reliable DEF storage performance.
By providing dependable diesel exhaust fluid storage and management, this urea tank contributes directly to SCR system efficiency, NOx emissions reduction, and maintained regulatory compliance in demanding transport and logistics environments.
The DZ9X259745022 60L urea tank is manufactured from premium high-quality urea-resistant polymer with precision molding processes, delivering exceptional dimensional accuracy and consistent fluid containment integrity.
The integrated level sensing system of the DZ9X259745022 provides accurate and continuous DEF quantity measurement, transmitting reliable fluid level information to the vehicle control module for proper SCR system management and driver notification.
The precisely engineered heating elements within the DZ9X259745022 enable rapid DEF thawing after cold starts and maintain proper fluid temperature, preventing freezing-related system blockage and ensuring continuous SCR dosing capability in winter conditions.
Each 60L urea tank undergoes rigorous quality verification, including dimensional inspection, leak testing, and integrated component function validation to guarantee reliable performance in demanding SCR aftertreatment system applications under all conditions.
The material selection for the DZ9X259745022 prioritizes both chemical compatibility with diesel exhaust fluid and impact strength for long-term durability in the exposed under-chassis vehicle environmental conditions.
The DZ9X259745022 60L urea tank’s design has been validated through extensive vehicle-level SCR system testing to ensure reliable DEF storage and management throughout the complete vehicle operational interval under all climate conditions.
Replacement of the DZ9X259745022 60L urea tank requires draining the remaining DEF from the old tank, disconnecting all supply lines, electrical connectors, and mounting hardware, and installing the new tank with proper alignment and secure fastening.
After installation of the DZ9X259745022 60L urea tank, verify that all fluid connections are properly tightened, electrical connectors are securely seated, the tank is correctly mounted, and the SCR system functions without DEF leaks or sensor communication errors.
Periodic inspection of the DZ9X259745022 60L urea tank for physical damage, DEF leaks, mounting bracket security, electrical connector condition, or contamination is recommended within routine vehicle SCR system maintenance and scheduled inspection intervals.
When installing the DZ9X259745022 60L urea tank, ensure that the mounting surfaces are clean, all brackets are properly aligned, and the tank is correctly positioned to prevent stress on supply lines and electrical connections during vehicle operation.
It is critical to use only specified diesel exhaust fluid meeting ISO 22241 standards when refilling the DZ9X259745022 urea tank, and to avoid contamination that could damage the SCR catalyst, level sensors, and compromise vehicle emissions compliance.
During routine vehicle service, pay close attention to the urea tank area of the DZ9X259745022 for signs of DEF crystallization around connections, physical impact damage, or level sensor malfunction indicating the need for immediate inspection and potential tank replacement.
Each DZ9X259745022 60L urea tank undergoes thorough dimensional inspection, leak testing, level sensor calibration verification, and heating function validation to guarantee strict compliance with OEM engineering specifications.
We provide complete quality documentation for every DZ9X259745022 60L urea tank, including material certifications and comprehensive inspection reports for vehicle maintenance records and workshop quality assurance compliance.
The 60L urea tank is tested for dimensional accuracy, fluid containment integrity, and integrated component function to ensure proper fitment and reliable DEF storage in the most demanding vehicle operating environments and climate conditions.
Our quality management system includes thermal cycling testing, chemical compatibility verification, and integrated component durability evaluation on the DZ9X259745022 to guarantee consistent manufacturing quality and extended service durability.
We maintain complete traceability of all materials and components used in the DZ9X259745022 60L urea tank, from raw material certification to finished product inspection, ensuring total accountability throughout the entire production and supply process.
Visible cracks, impact damage, or DEF leakage from the DZ9X259745022 60L urea tank indicates structural failure, requiring immediate replacement to restore proper SCR system function and prevent emissions non-compliance during vehicle operation.
DEF crystallization around connections, tank body deformation, or internal contamination of the DZ9X259745022 suggests tank integrity compromise, necessitating prompt replacement during scheduled SCR aftertreatment system inspection and maintenance operations.
If the urea tank exhibits level sensor malfunction, heating element failure, or mounting bracket breakage, the DZ9X259745022 component should be replaced immediately to restore proper DEF storage, monitoring, and SCR system dosing function.
Following any under-chassis impact, collision damage, or SCR system contamination event affecting the urea tank area, the DZ9X259745022 60L urea tank must be thoroughly inspected and replaced if any damage or leakage is detected during professional examination.
If the tank shows signs of internal contamination affecting DEF quality, inaccurate level readings, or difficulty in maintaining proper SCR system pressure, the DZ9X259745022 requires replacement to ensure correct emissions control system performance.
Standard comprehensive vehicle inspections should include a detailed evaluation of the DZ9X259745022 60L urea tank for early indicators of physical damage, DEF leakage, or integrated component malfunction requiring prompt corrective maintenance action.
Inferior aftermarket urea tanks with incorrect material specifications or substandard molding quality can lead to SCR system failure and emissions non-compliance penalties. We exclusively supply authentic components like the DZ9X259745022 manufactured to precise OEM engineering and quality standards.
The part number DZ9X259745022 is clearly identified on the packaging for unambiguous verification. Our extensive international logistics infrastructure ensures secure protective packaging and rapid dispatch to any worldwide destination with complete export documentation and customs compliance.
All procurements of DZ9X259745022 include comprehensive quality certification, ensuring conformity with local import regulations and vehicle SCR aftertreatment system documentation requirements applicable in your jurisdiction and operational region.
We provide highly competitive pricing structures and dependable shipping alternatives for the DZ9X259745022 60L urea tank, facilitating convenient access for our international clientele to maintain their Shacman trucks with authentic OEM SCR storage components.
Our dedicated client support team stands prepared to address any technical inquiries or logistical concerns regarding the DZ9X259745022 60L urea tank, encompassing vehicle emissions system consultations to comprehensive bulk fleet procurement processing and delivery coordination.
Complete DZ9X259745022 60L urea tank. Ready for professional installation featuring precision-molded urea-resistant construction, 60-liter capacity, integrated level sensor and heating elements, and durable polymer body for dependable diesel exhaust fluid storage.
Expert technical guidance on vehicle SCR aftertreatment storage components and proper installation procedures for the DZ9X259745022 60L urea tank is readily available. We assist in ensuring reliable DEF storage and emissions control for your Shacman H3000 truck application.
Complete quality documentation for DZ9X259745022 is available upon request, encompassing material certifications and dimensional inspection reports for your permanent maintenance and vehicle service records.
For current stock availability of the genuine DZ9X259745022 60L urea tank, please use the contact buttons above.