DZ97259740516
Genuine Shacman X5000 Integrated Electromagnetic Water Valve Assembly DZ97259740516 – SCR Heating Control Solution
2026-06-03
DZ95259740384
Genuine Shacman X5000 Urea Tank Bracket DZ95259740384 – Sturdy DEF Reservoir Support
2026-06-03

Genuine Shacman X5000 Urea Tank Liquid Level Sensor Body DZ95259740568 – Precision DEF Level Monitoring Housing

Urea Tank Liquid Level Sensor Body DZ95259740568

Urea Tank Liquid Level Sensor Body

Корпус датчика уровня мочевины DZ95259740568

Корпус Датчика Уровня

Cuerpo del sensor de nivel de urea DZ95259740568

Cuerpo del Sensor de Nivel

OEM Urea Tank Liquid Level Sensor Body DZ95259740568 precision‑molded for the Shacman X5000 SCR system. This durable DZ95259740568 housing encloses the level sensing mechanism, providing accurate DEF quantity measurement while protecting internal components from contamination.

Constructed from chemical‑resistant engineering polymer with integrated sealing features, the Urea Tank Liquid Level Sensor Body DZ95259740568 ensures reliable level monitoring throughout the vehicle’s emissions system service life.

Replacing a damaged sensor body with the genuine DZ95259740568 component restores accurate DEF level indication and prevents the false readings that can lead to unexpected fluid depletion.

Technical Specifications

Parameter Specification
OEM Part NumberDZ95259740568
Product NameUrea Tank Liquid Level Sensor Body
Brand / ModelShacman X5000
Housing MaterialPolyoxymethylene with EPDM Sealing Elements
Probe Length380.00 mm from mounting flange
Mounting Flange Pattern6‑bolt circular pattern, 72 mm PCD
Electrical Connector Type4‑pin integral molded connector
Operating Temperature-40°C to +85°C
Chemical ResistanceExcellent resistance to urea solution and diesel fuel
ApplicationShacman X5000 urea tank level sensing assembly

The Function of the Sensor Body Assembly

The DZ95259740568 urea tank liquid level sensor body houses the precision sensing elements that measure the quantity of diesel exhaust fluid remaining in the storage tank. It provides critical data to the engine control module.

Accurate DEF level information allows the vehicle operator to plan refueling stops and prevents the system from running empty, which would trigger SCR system faults and potential engine derate conditions under emissions regulations.

The Urea Tank Liquid Level Sensor Body DZ95259740568 also provides the structural mounting platform that positions the sensing probe at the correct depth within the tank for accurate measurement across the full fluid range.

Chemical‑Resistant Polyoxymethylene Construction

The DZ95259740568 sensor body is molded from polyoxymethylene, an engineering thermoplastic selected for its outstanding dimensional stability and resistance to the alkaline urea solution used in SCR systems.

Integrated EPDM sealing elements at the flange interface and electrical connector ensure that the sensor body maintains a watertight seal against the tank, preventing DEF leakage and protecting the internal electronics from moisture.

Installation and Sealing Procedures

The DZ95259740568 sensor body mounts to the urea tank using six bolts that compress the integrated flange gasket against the tank mounting surface. The bolts must be tightened evenly in a star pattern to ensure uniform seal compression.

The tank mounting surface must be clean and free of crystallized urea deposits before installation. Any residue on the sealing surface can prevent proper gasket contact and lead to fluid leakage around the sensor flange.

Quality Control and Dimensional Verification

Each production batch of DZ95259740568 sensor bodies is sampled for dimensional inspection using coordinate measuring equipment. Flange flatness, bolt hole position, and probe length are verified against engineering specifications.

The integral connector is tested for proper pin retention and electrical continuity. The sealing elements undergo compression set testing to confirm they maintain their elastic properties after extended exposure to DEF solution.

Signs of Sensor Body Deterioration

Crystallized urea deposits around the DZ95259740568 sensor flange indicate that the sealing gasket has failed and is allowing DEF to seep past the mounting surface. The sensor body should be removed and inspected.

A cracked or deformed sensor body may allow moisture to enter the internal electronics, causing erratic level readings or complete sensor failure. Physical damage to the housing requires immediate sensor replacement.

During urea tank service, the sensor body exterior should be cleaned and inspected for signs of chemical attack or mechanical damage. The electrical connector should be checked for corrosion or terminal spreading.

Compatibility and Fleet Standardization

The DZ95259740568 sensor body is specifically configured for the Shacman X5000 urea tank flange pattern and depth requirements. Its probe length and mounting dimensions match this vehicle platform exactly.

Fleet operators should maintain spare sensor body assemblies for rapid replacement when physical damage or seal failure occurs. Timely replacement prevents the SCR system faults associated with inaccurate DEF level readings.

Genuine OEM Parts and Worldwide Distribution

Aftermarket sensor bodies with incorrect probe calibration or inferior sealing materials can provide inaccurate level data. We supply only the authentic Shacman X5000 Urea Tank Liquid Level Sensor Body DZ95259740568.

Each sensor body is individually packaged with protective covers over the probe and connector. The part number DZ95259740568 is clearly printed on both the component and its packaging for immediate identification.

Our international logistics network ensures that genuine DZ95259740568 sensor body assemblies are available for immediate dispatch to dealerships and fleet maintenance facilities across all major continents.

Package Contents

Complete liquid level sensor body with integrated seals and electrical connector. Factory‑tested and ready for installation into the urea tank.

Technical Support

Expert guidance on sensor body installation and urea tank sealing procedures. We help ensure your DZ95259740568 assembly provides accurate DEF level monitoring.

For current stock availability and pricing on the genuine Urea Tank Liquid Level Sensor Body DZ95259740568, please use the contact buttons above.

Hot Sale Shacman X5000 Parts

Recent News

2026-05-29

Shacman X5000 Front Leaf Spring Lug Assembly

Shacman X5000 Work Light Clamp Seat Assembly – OEM-grade clamp & square nut for durable truck lighting.
2026-05-27

Shacman X5000 Left Connecting Plate Assembly

Shacman X5000 Work Light Clamp Seat Assembly – OEM-grade clamp & square nut for durable truck lighting.
2026-05-29

Shacman X5000 Radiator Support Bracket Assembly

Shacman X5000 Work Light Clamp Seat Assembly – OEM-grade clamp & square nut for durable truck lighting.
2026-05-29

Shacman X5000 Steering Control

Shacman X5000 Work Light Clamp Seat Assembly – OEM-grade clamp & square nut for durable truck lighting.
2026-05-29

Shacman X5000 Bearing Seat Assembly

Shacman X5000 Work Light Clamp Seat Assembly – OEM-grade clamp & square nut for durable truck lighting.
2026-05-27

Shacman X5000 Fuel Supply System

Shacman X5000 Work Light Clamp Seat Assembly – OEM-grade clamp & square nut for durable truck lighting.
Chat with us
Chat with us
Questions, doubts, issues? We're here to help you!
Connecting...
Please leave your inquiry and your phone. We will give you feedback within 12 hours.
Our operators are busy. Please try again later
:
:
:
:
Have you got question? Write to us! Please leave your phone or what'sApp
:
:
This chat session has ended